@@ -11,7 +11,7 @@ from dcim.models import *
|
|
|
from extras.events import serialize_for_event
|
|
|
from extras.models import CustomField
|
|
|
from ipam.models import Prefix
|
|
|
-from netbox.choices import DiameterUnitChoices, WeightUnitChoices
|
|
|
+from netbox.choices import DiameterUnitChoices, TemperatureUnitChoices, WeightUnitChoices
|
|
|
from tenancy.models import Tenant
|
|
|
from utilities.data import drange
|
|
|
from virtualization.models import Cluster, ClusterType
|
|
|
@@ -2925,3 +2925,59 @@ class CoolingComponentTestCase(TestCase):
|
|
|
|
|
|
with self.assertRaises(ValidationError):
|
|
|
cooling_outlet.full_clean()
|
|
|
+
|
|
|
+ def test_cooling_source_location_site_mismatch(self):
|
|
|
+ """
|
|
|
+ CoolingSource.clean() should raise a ValidationError when its location belongs to a different site.
|
|
|
+ """
|
|
|
+ site2 = Site.objects.create(name='Site 2', slug='site-2')
|
|
|
+ location = Location.objects.create(name='Location 1', slug='location-1', site=site2)
|
|
|
+ cooling_source = CoolingSource(
|
|
|
+ site=self.site,
|
|
|
+ location=location,
|
|
|
+ name='Cooling Source 1',
|
|
|
+ status=CoolingSourceStatusChoices.STATUS_ACTIVE,
|
|
|
+ )
|
|
|
+ with self.assertRaises(ValidationError):
|
|
|
+ cooling_source.full_clean()
|
|
|
+
|
|
|
+ def test_cooling_source_temperature_without_unit(self):
|
|
|
+ """
|
|
|
+ CoolingSource.clean() should raise a ValidationError when a temperature is set without a unit.
|
|
|
+ """
|
|
|
+ cooling_source = CoolingSource(
|
|
|
+ site=self.site,
|
|
|
+ name='Cooling Source 2',
|
|
|
+ status=CoolingSourceStatusChoices.STATUS_ACTIVE,
|
|
|
+ supply_temperature=Decimal('18'),
|
|
|
+ )
|
|
|
+ with self.assertRaises(ValidationError):
|
|
|
+ cooling_source.full_clean()
|
|
|
+
|
|
|
+ # Setting a unit should resolve the error and populate the normalized value on save
|
|
|
+ cooling_source.temperature_unit = TemperatureUnitChoices.UNIT_CELSIUS
|
|
|
+ cooling_source.full_clean()
|
|
|
+ cooling_source.save()
|
|
|
+ self.assertEqual(cooling_source._abs_supply_temperature, Decimal('18.0000'))
|
|
|
+
|
|
|
+ def test_cooling_feed_rack_site_mismatch(self):
|
|
|
+ """
|
|
|
+ CoolingFeed.clean() should raise a ValidationError when its rack is in a different site than the
|
|
|
+ cooling source.
|
|
|
+ """
|
|
|
+ site2 = Site.objects.create(name='Site 3', slug='site-3')
|
|
|
+ cooling_source = CoolingSource.objects.create(
|
|
|
+ site=self.site,
|
|
|
+ name='Cooling Source 3',
|
|
|
+ status=CoolingSourceStatusChoices.STATUS_ACTIVE,
|
|
|
+ )
|
|
|
+ rack = Rack.objects.create(name='Rack 1', site=site2, status=RackStatusChoices.STATUS_ACTIVE)
|
|
|
+ cooling_feed = CoolingFeed(
|
|
|
+ cooling_source=cooling_source,
|
|
|
+ rack=rack,
|
|
|
+ name='Cooling Feed 1',
|
|
|
+ status=CoolingFeedStatusChoices.STATUS_ACTIVE,
|
|
|
+ type=CoolingFeedTypeChoices.TYPE_SUPPLY,
|
|
|
+ )
|
|
|
+ with self.assertRaises(ValidationError):
|
|
|
+ cooling_feed.full_clean()
|