@@ -751,6 +751,8 @@ class DeviceTypeFilterSet(PrimaryModelFilterSet):
|
|
|
'console_server_port_template_count',
|
|
|
'power_port_template_count',
|
|
|
'power_outlet_template_count',
|
|
|
+ 'cooling_port_template_count',
|
|
|
+ 'cooling_outlet_template_count',
|
|
|
'interface_template_count',
|
|
|
'front_port_template_count',
|
|
|
'rear_port_template_count',
|
|
|
@@ -894,6 +896,8 @@ class ModuleTypeFilterSet(AttributeFiltersMixin, PrimaryModelFilterSet):
|
|
|
'console_server_port_template_count',
|
|
|
'power_port_template_count',
|
|
|
'power_outlet_template_count',
|
|
|
+ 'cooling_port_template_count',
|
|
|
+ 'cooling_outlet_template_count',
|
|
|
'interface_template_count',
|
|
|
'front_port_template_count',
|
|
|
'rear_port_template_count',
|
|
|
@@ -1514,6 +1518,8 @@ class DeviceFilterSet(
|
|
|
'console_server_port_count',
|
|
|
'power_port_count',
|
|
|
'power_outlet_count',
|
|
|
+ 'cooling_port_count',
|
|
|
+ 'cooling_outlet_count',
|
|
|
'interface_count',
|
|
|
'front_port_count',
|
|
|
'rear_port_count',
|
|
|
@@ -2824,6 +2830,15 @@ class CableFilterSet(TenancyFilterSet, PrimaryModelFilterSet):
|
|
|
powerfeed_id = MultiValueNumberFilter(
|
|
|
method='filter_by_powerfeed'
|
|
|
)
|
|
|
+ coolingport_id = MultiValueNumberFilter(
|
|
|
+ method='filter_by_coolingport'
|
|
|
+ )
|
|
|
+ coolingoutlet_id = MultiValueNumberFilter(
|
|
|
+ method='filter_by_coolingoutlet'
|
|
|
+ )
|
|
|
+ coolingfeed_id = MultiValueNumberFilter(
|
|
|
+ method='filter_by_coolingfeed'
|
|
|
+ )
|
|
|
circuittermination_id = MultiValueNumberFilter(
|
|
|
method='filter_by_circuittermination'
|
|
|
)
|
|
|
@@ -2903,6 +2918,15 @@ class CableFilterSet(TenancyFilterSet, PrimaryModelFilterSet):
|
|
|
def filter_by_powerfeed(self, queryset, name, value):
|
|
|
return self.filter_by_termination_object(queryset, PowerFeed, value)
|
|
|
|
|
|
+ def filter_by_coolingport(self, queryset, name, value):
|
|
|
+ return self.filter_by_termination_object(queryset, CoolingPort, value)
|
|
|
+
|
|
|
+ def filter_by_coolingoutlet(self, queryset, name, value):
|
|
|
+ return self.filter_by_termination_object(queryset, CoolingOutlet, value)
|
|
|
+
|
|
|
+ def filter_by_coolingfeed(self, queryset, name, value):
|
|
|
+ return self.filter_by_termination_object(queryset, CoolingFeed, value)
|
|
|
+
|
|
|
def filter_by_circuittermination(self, queryset, name, value):
|
|
|
return self.filter_by_termination_object(queryset, CircuitTermination, value)
|
|
|
|
|
|
@@ -2941,6 +2965,15 @@ class CableTerminationFilterSet(ChangeLoggedModelFilterSet):
|
|
|
powerfeed_id = MultiValueNumberFilter(
|
|
|
method='filter_by_powerfeed'
|
|
|
)
|
|
|
+ coolingport_id = MultiValueNumberFilter(
|
|
|
+ method='filter_by_coolingport'
|
|
|
+ )
|
|
|
+ coolingoutlet_id = MultiValueNumberFilter(
|
|
|
+ method='filter_by_coolingoutlet'
|
|
|
+ )
|
|
|
+ coolingfeed_id = MultiValueNumberFilter(
|
|
|
+ method='filter_by_coolingfeed'
|
|
|
+ )
|
|
|
circuittermination_id = MultiValueNumberFilter(
|
|
|
method='filter_by_circuittermination'
|
|
|
)
|
|
|
@@ -2977,6 +3010,15 @@ class CableTerminationFilterSet(ChangeLoggedModelFilterSet):
|
|
|
def filter_by_powerfeed(self, queryset, name, value):
|
|
|
return self.filter_by_termination_object(queryset, PowerFeed, value)
|
|
|
|
|
|
+ def filter_by_coolingport(self, queryset, name, value):
|
|
|
+ return self.filter_by_termination_object(queryset, CoolingPort, value)
|
|
|
+
|
|
|
+ def filter_by_coolingoutlet(self, queryset, name, value):
|
|
|
+ return self.filter_by_termination_object(queryset, CoolingOutlet, value)
|
|
|
+
|
|
|
+ def filter_by_coolingfeed(self, queryset, name, value):
|
|
|
+ return self.filter_by_termination_object(queryset, CoolingFeed, value)
|
|
|
+
|
|
|
def filter_by_circuittermination(self, queryset, name, value):
|
|
|
return self.filter_by_termination_object(queryset, CircuitTermination, value)
|
|
|
|