@@ -2966,7 +2966,7 @@ class PowerFeed(ChangeLoggedModel, CableTermination, CustomFieldModel):
|
|
|
available_power = models.PositiveSmallIntegerField(
|
|
available_power = models.PositiveSmallIntegerField(
|
|
|
default=0
|
|
default=0
|
|
|
)
|
|
)
|
|
|
- power_factor = models.PositiveSmallIntegerField(
|
|
|
|
|
|
|
+ max_utilization = models.PositiveSmallIntegerField(
|
|
|
validators=[MinValueValidator(1), MaxValueValidator(100)],
|
|
validators=[MinValueValidator(1), MaxValueValidator(100)],
|
|
|
default=80,
|
|
default=80,
|
|
|
help_text="Maximum permissible draw (percentage)"
|
|
help_text="Maximum permissible draw (percentage)"
|
|
@@ -2984,7 +2984,7 @@ class PowerFeed(ChangeLoggedModel, CableTermination, CustomFieldModel):
|
|
|
|
|
|
|
|
csv_headers = [
|
|
csv_headers = [
|
|
|
'site', 'panel_name', 'rack_group', 'rack_name', 'name', 'status', 'type', 'supply', 'phase', 'voltage',
|
|
'site', 'panel_name', 'rack_group', 'rack_name', 'name', 'status', 'type', 'supply', 'phase', 'voltage',
|
|
|
- 'amperage', 'power_factor', 'comments',
|
|
|
|
|
|
|
+ 'amperage', 'max_utilization', 'comments',
|
|
|
]
|
|
]
|
|
|
|
|
|
|
|
class Meta:
|
|
class Meta:
|
|
@@ -3008,7 +3008,7 @@ class PowerFeed(ChangeLoggedModel, CableTermination, CustomFieldModel):
|
|
|
self.get_phase_display(),
|
|
self.get_phase_display(),
|
|
|
self.voltage,
|
|
self.voltage,
|
|
|
self.amperage,
|
|
self.amperage,
|
|
|
- self.power_factor,
|
|
|
|
|
|
|
+ self.max_utilization,
|
|
|
self.comments,
|
|
self.comments,
|
|
|
)
|
|
)
|
|
|
|
|
|
|
@@ -3023,7 +3023,7 @@ class PowerFeed(ChangeLoggedModel, CableTermination, CustomFieldModel):
|
|
|
def save(self, *args, **kwargs):
|
|
def save(self, *args, **kwargs):
|
|
|
|
|
|
|
|
# Cache the available_power property on the instance
|
|
# Cache the available_power property on the instance
|
|
|
- kva = self.voltage * self.amperage * (self.power_factor / 100)
|
|
|
|
|
|
|
+ kva = self.voltage * self.amperage * (self.max_utilization / 100)
|
|
|
if self.phase == POWERFEED_PHASE_3PHASE:
|
|
if self.phase == POWERFEED_PHASE_3PHASE:
|
|
|
self.available_power = round(kva * 1.732)
|
|
self.available_power = round(kva * 1.732)
|
|
|
self.available_power = round(kva)
|
|
self.available_power = round(kva)
|