@@ -43,18 +43,6 @@ changes in the database indefinitely.
|
|
|
|
|
|
|
|
---
|
|
---
|
|
|
|
|
|
|
|
-## JOBRESULT_RETENTION
|
|
|
|
|
-
|
|
|
|
|
-Default: 90
|
|
|
|
|
-
|
|
|
|
|
-The number of days to retain job results (scripts and reports). Set this to `0` to retain
|
|
|
|
|
-job results in the database indefinitely.
|
|
|
|
|
-
|
|
|
|
|
-!!! warning
|
|
|
|
|
- If enabling indefinite job results retention, it is recommended to periodically delete old entries. Otherwise, the database may eventually exceed capacity.
|
|
|
|
|
-
|
|
|
|
|
----
|
|
|
|
|
-
|
|
|
|
|
## CUSTOM_VALIDATORS
|
|
## CUSTOM_VALIDATORS
|
|
|
|
|
|
|
|
This is a mapping of models to [custom validators](../customization/custom-validation.md) that have been defined locally to enforce custom validation logic. An example is provided below:
|
|
This is a mapping of models to [custom validators](../customization/custom-validation.md) that have been defined locally to enforce custom validation logic. An example is provided below:
|
|
@@ -110,6 +98,18 @@ Setting this to False will disable the GraphQL API.
|
|
|
|
|
|
|
|
---
|
|
---
|
|
|
|
|
|
|
|
|
|
+## JOBRESULT_RETENTION
|
|
|
|
|
+
|
|
|
|
|
+Default: 90
|
|
|
|
|
+
|
|
|
|
|
+The number of days to retain job results (scripts and reports). Set this to `0` to retain
|
|
|
|
|
+job results in the database indefinitely.
|
|
|
|
|
+
|
|
|
|
|
+!!! warning
|
|
|
|
|
+ If enabling indefinite job results retention, it is recommended to periodically delete old entries. Otherwise, the database may eventually exceed capacity.
|
|
|
|
|
+
|
|
|
|
|
+---
|
|
|
|
|
+
|
|
|
## MAINTENANCE_MODE
|
|
## MAINTENANCE_MODE
|
|
|
|
|
|
|
|
Default: False
|
|
Default: False
|
|
@@ -185,6 +185,30 @@ The default maximum number of objects to display per page within each list of ob
|
|
|
|
|
|
|
|
---
|
|
---
|
|
|
|
|
|
|
|
|
|
+## POWERFEED_DEFAULT_AMPERAGE
|
|
|
|
|
+
|
|
|
|
|
+Default: 15
|
|
|
|
|
+
|
|
|
|
|
+The default value for the `amperage` field when creating new power feeds.
|
|
|
|
|
+
|
|
|
|
|
+---
|
|
|
|
|
+
|
|
|
|
|
+## POWERFEED_DEFAULT_MAX_UTILIZATION
|
|
|
|
|
+
|
|
|
|
|
+Default: 80
|
|
|
|
|
+
|
|
|
|
|
+The default value (percentage) for the `max_utilization` field when creating new power feeds.
|
|
|
|
|
+
|
|
|
|
|
+---
|
|
|
|
|
+
|
|
|
|
|
+## POWERFEED_DEFAULT_VOLTAGE
|
|
|
|
|
+
|
|
|
|
|
+Default: 120
|
|
|
|
|
+
|
|
|
|
|
+The default value for the `voltage` field when creating new power feeds.
|
|
|
|
|
+
|
|
|
|
|
+---
|
|
|
|
|
+
|
|
|
## PREFER_IPV4
|
|
## PREFER_IPV4
|
|
|
|
|
|
|
|
Default: False
|
|
Default: False
|