@@ -24,7 +24,7 @@ my $mountpoint2_valid = getTestParameter( "NP_MOUNTPOINT2_VALID", "Path to anoth
|
|
|
if ($mountpoint_valid eq "" or $mountpoint2_valid eq "") {
|
|
|
plan skip_all => "Need 2 mountpoints to test";
|
|
|
} else {
|
|
|
- plan tests => 57;
|
|
|
+ plan tests => 61;
|
|
|
}
|
|
|
|
|
|
$result = NPTest->testCmd(
|
|
|
@@ -76,6 +76,24 @@ if ($free_inode_on_mp1 > $free_inode_on_mp2) {
|
|
|
die "Two mountpoints with same inodes free - cannot do rest of test";
|
|
|
}
|
|
|
|
|
|
+# Verify performance data
|
|
|
+# First check absolute thresholds...
|
|
|
+$result = NPTest->testCmd(
|
|
|
+ "./check_disk -w 20 -c 10 -p $mountpoint_valid"
|
|
|
+ );
|
|
|
+$_ = $result->perf_output;
|
|
|
+my ($warn_absth_data, $crit_absth_data) = (m/=.[^;]*;(\d+);(\d+);\d+;\d+/);
|
|
|
+is ($warn_absth_data, 20, "Wrong warning in perf data using absolute thresholds");
|
|
|
+is ($crit_absth_data, 10, "Wrong critical in perf data using absolute thresholds");
|
|
|
+
|
|
|
+# Then check percent thresholds.
|
|
|
+$result = NPTest->testCmd(
|
|
|
+ "./check_disk -w 20% -c 10% -p $mountpoint_valid"
|
|
|
+ );
|
|
|
+$_ = $result->perf_output;
|
|
|
+my ($warn_percth_data, $crit_percth_data, $total_percth_data) = (m/=.[^;]*;(\d+);(\d+);\d+;(\d+)/);
|
|
|
+is ($warn_percth_data, int($total_percth_data/100*20), "Wrong warning in perf data using percent thresholds");
|
|
|
+is ($crit_percth_data, int($total_percth_data/100*10), "Wrong critical in perf data using percent thresholds");
|
|
|
|
|
|
|
|
|
# Check when order of mount points are reversed, that perf data remains same
|